光宇蓄电池12V电池2V蓄电池长久耐用:
光宇蓄电池12V电池2V蓄电池长久耐用:光宇电池 总部在哈尔滨  高技术研发铅酸 胶体免维护蓄电池  12V2V电池在国内用于电力发电    直流发电   应急电源供电    ups电源供电     EPS系统  ,

长寿命、高容量、优越的过放电后的恢复性;

气密性好、安全性高、可快速充电;

防漏液的结构、具有免维护的特性;

具有抗过充电、抗过放电、耐振动、耐冲击的特点,

 

可任意位置放置,便于保护和使用;

能量密度的提高,实现了电池的小型化,轻量化;

能满足客户需要,被广泛应用于各个领域

 

长寿命、高容量、优越的过放电后的恢复性;

气密性好、安全性高、可快速充电;

防漏液的结构、具有免维护的特性;

具有抗过充电、抗过放电、耐振动、耐冲击的特点,

 

可任意位置放置,便于保护和使用;

能量密度的提高,实现了电池的小型化,轻量化;

能满足客户需要,被广泛应用于各个领域

 

光宇蓄电池1) Battery Installation
Batteries should be installed in clean, cool, ventilated and dry places as far as possible, and should avoid being affected by sunlight, heaters or other radiation sources. Batteries should be positively placed, not tilted. The terminals of each battery should be firmly connected.  光宇电池   光宇铅酸蓄电池    光宇胶体蓄电池  

光宇蓄电池2) ambient temperature
The ambient temperature has a great influence on the battery. If the ambient temperature is too high, the battery will be overcharged to produce gas. If the ambient temperature is too low, the battery will be overcharged to produce gas.
It will cause the battery to be undercharged, which will affect the service life of the battery. Therefore, the ambient temperature is generally required to be around 25 C, and the floating charge voltage of Shante UPS is also set according to this temperature.

光宇蓄电池3) Charge-discharge current
Charging and discharging currents of batteries are generally expressed in terms of C. The actual value of C is related to the capacity of batteries. For example, if it's a 100AH battery: C = 100A. The optimum charging current of Matsushita lead-acid maintenance-free battery is about 0.1C, and the charging current must not be greater than 0.3C. Excessive or low charging current will affect the service life of batteries. Discharge current generally requires 0.05~3C, UPS can meet this requirement in normal use, but also to prevent accidents, such as battery short circuit.

4) Charging Voltage
Because UPS batteries belong to standby mode of operation, they are in charge state under normal conditions, and discharge only when power failure occurs. In order to prolong the service life of batteries, Shante UPS chargers are generally controlled by constant voltage and current limitation. When the batteries are full, they will be converted to floating charging state. The floating charging voltage of each cell is set at about 13.7V. If the charging voltage is too high, the battery will be overcharged, and vice versa, the battery will be undercharged. The abnormal charging voltage may be caused by the incorrect battery configuration or the failure of charger. Therefore, when installing batteries, we must pay attention to the correctness of the specifications and quantities of batteries. Batteries of different specifications and batches should not be mixed. External charger should not use inferior charger, and heat dissipation should be considered when installing.

光宇蓄电池5) Depth of discharge
The effect of discharge depth on battery life is also very large. The deeper the discharge depth, the less the number of cycles it uses. Therefore, deep discharge should be avoided in use. Although Shante UPS has the function of battery low potential protection, when a single battery discharges to about 10.5V, UPS will automatically shut down, but if UPS is discharged under light or no-load conditions, it will also cause deep discharges of batteries.

光宇蓄电池6) Regular maintenance
Batteries should be checked regularly after a certain period of time, such as observing whether their appearance is abnormal, measuring whether the voltage of each battery is average, etc. If the battery is not powered up for a long time, it will always be in charge state, which will make the battery's activity worse. Therefore, even if the battery is not powered off, UPS also needs to conduct periodic discharge tests to maintain the battery. Activity.